Cleveland Convotherm PC-HACCP Manuel d'installation

Naviguer en ligne ou télécharger Manuel d'installation pour PC/postes de travail Cleveland Convotherm PC-HACCP. Cleveland Convotherm PC-HACCP Installation manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 30
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
260AZH REV. B 3/06
This kit connects a PC to as many as 31 Combis at a maximum distance of 3280 Feet (1000 meters). The
software can download cooking programs, record HACCP information, and monitor the networked
Combis in real-time. This installation manual includes instructions for both RS232 and USB connections
for a PC. Choose the connection that works best for your application and follow the instructions that
apply. If any parts are missing from any kits, please contact Cleveland Range Service at 216-481-4900.
RS232 Correct connection of a PC to Combis using the Communication Module with RS232 Port.
FOR RS232 connection use part number: CPC-HACCP-MU232
Correct connection of a PC to Combis using the Communication Module with USB Port.
FOR USB connection use part number: CPC-HACCP-MUUSB
CAUTION
Turn off all power to Combis before installation of PC-HACCP Network.
Follow all Safety and Operating Instructions
Failure to do so can result in injury, and equipment and property damage.
PC-Control / HACCP Network Installation
For Convotherm by Cleveland Combination Oven Steamers
1333 East 179
th
Street
Cleveland, Ohio 44110
Phone: (216) 481-4900
Fax: (216) 481 3782
www.clevelandrange.com
Vue de la page 0
1 2 3 4 5 6 ... 29 30

Résumé du contenu

Page 1 - CAUTION

260AZH REV. B 3/06 This kit connects a PC to as many as 31 Combis at a maximum distance of 3280 Feet (1000 meters). The software can download cooki

Page 2

10 Attaching the Base Plate to the Communication Module Mount the board to the panel using the spacers and nuts included in the kit.

Page 3

11Inserting the Communication Module Cable into the Oven Photo 30 Remove the sanitary seal plug from the underside of the Combi.

Page 4

12Photo 25Photo 26Connect the Network Cable to the Communication Module Take care to match the wire ends or colors to the connections throughout the

Page 5

13 Setting the Jumpers on the Communication Module Photo 27 Jumper setting for the first Combi and all Combis in the Network. To set the jumpers:

Page 6

14 Photo 33 Secure cable to the upper right spacer as shown in Photo 36. Photo 35 Place Control Board and Module back in

Page 7 - Photo 14

15Replace the Operation Panel Photo 36 Remount the Operation Panel back into the Combi. Photo 37 Press down and turn clockwise to tighten the Op

Page 8 - Photo 19

16Replace the Control Side Panel Photo 38 Photo 39 Push up and in from the bottom edge of the side panel.

Page 9 - Photo 21

17Directions for Installing the USB Adapter 1. Plug the USB connector into the adapter and connect to one of the USB ports on the back of your com

Page 10 - Photo 22 Photo 23

18 Select install from a list of specific location (advanced) Ignore this screen if it appears:

Page 11 - Photo 31

19 Uncheck “Include this location in the search.” Click Next. Let search

Page 12

21 Software-CD - 300550 2 Network Connection Cable – 300551 (included only w/ 232 kit) 3 Dongle - C5009210 4 PC Interface Converter - C5009156 (inclu

Page 13 - Photo 28

20 The Hardware wizard will appear a second time:

Page 14 - Photo 35

21 Follow the directions in each screen.

Page 15

22 Allow search for CD

Page 16

23 Click Finish to close the screen. Configure your serial device: 1. Right click My Computer, select properties: Then select the “Hardware t

Page 17

24 Expand the Ports (COM & LPT) device

Page 18

25 Right click on the “USB Serial Port (COM??)” item. The ?? will be a number greater than 0 and less than 255. Select the Port Settings tab.

Page 19

26 Note the COM setting. Only COM1, COM2, COM3, and COM4 can be used by the HACCP software. To change the COM number, click the Advanced button.

Page 20

27 If needed click the COM Port Number: drop menu and select and acceptable port number. If all are marked as (in use) then change one of the other

Page 21

28For USB to RS485 Switches 1 and 4 are ONFor USB to RS232 Switches 2, 3, 4 are ON 6. Once the computer recognizes the USB adapter, the dip switch

Page 22

29Jumper #1 Position SHOWS WIRE CONNECTIONS PIN 1, PIN 2, AND GROUND (PIN 6). 7. For the adapter to output data for RS485, a jump

Page 23

31 Electronic Board (1) – C5019104 2 Connector (1) – C5002091 3 Bracket with Studs (1) – C2114799 4 Control Panel Spacers (2) – C8009030 5 Screws – M

Page 24

260AZH REV. B Rev Page116 March 2006 This Page for Internal Record Only, Not for Printing Cleveland Range, LLC 1333 East 179th St, Cleveland, Ohio 4

Page 25

4TO CONNECT THE RS232 CONVERTER TO THE PC Photos 4, 5, and 6 show the correct cable connections from the PC to the PC Converter for RS232. Note the

Page 26

5NOTE: A: RED WIRE B: BLACK WIRE GROUND: GROUND OR SHIELD WIRE RS232 CABLE CONNECTION FOR CONVERTER TO RS485 ONLY Photo 8 shows the cable connection

Page 27

6 TO CONNECT USB CONVERTER TO RS485 ONLY IMPORTANT: ALWAYS USE THE SAME USB PORT WHEN REATTACHING THE USB CABLE TO THE PC! See Page 20 for instruct

Page 28

7Remove the Control Side Cover Turn the 1/4 turn quick-locks to loosen. From the bottom edge of the side panel, push up and pull out. Rem

Page 29

8 Remove the Control Panel Photo 17 Press down and turn counterclockwise to remove the Operation Panel retention screw. Pho

Page 30 - 116 March 2006

9Attaching the Base Plate to the Communication Module 1. Mount the board to the panel using the spacers, nuts and washers included in the kit.