Cleveland KEL-40-INS Manuel de service

Naviguer en ligne ou télécharger Manuel de service pour Bouilloires électriques Cleveland KEL-40-INS. Cleveland KEL-40-INS Service manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 29
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
1333 East 179th St., Cleveland, Ohio, U.S.A. 44110
Phone: (216) 481-4900 Fax: (216) 481-3782
Visit our web site at www.clevelandrange.com
SE95036 Rev. 6
Operators Manual
Installation, Operation & Service
Electric Floor Model Kettles
For units built after August 1999
MODELS:
KEL-25, KEL-30, KEL-40, KEL-40-SH, KEL-60, KEL-80, KEL-100
KEL-25-T, KEL-40-T, KEL-60-T, KEL-80-T, KEL-100-T
KEL-40-SH, KEL-40-TSH, KEL-60-SH, KEL-60-TSH
Clev elan
d
Enodis
Vue de la page 0
1 2 3 4 5 6 ... 28 29

Résumé du contenu

Page 1 - Clev elan

1333 East 179th St., Cleveland, Ohio, U.S.A. 44110Phone: (216) 481-4900 Fax: (216) 481-3782Visit our web site at www.clevelandrange.comSE95036 Rev.

Page 2 - For your safety

FAUCET ASSEMBLYITEM PART DESCRIPTION QTY.NO. NO.1. KE50825-5 3/4" Spout . . . . . . . . . . . . . . . . . . . . . .1(KEL-25/30/40/60/80/100 &

Page 3 - INSTALLATION

HINGE ASSEMBLY153213126471181099ITEM NO. PART NO. DESCRIPTION QTY.Hinge Assembly1. - 11 KE50597-1 25 - 40 Gallon, 20 Gallon Full Jacketed . . . . . .

Page 4 - WIRE CONNECTION

ITEM NO. PART NO. DESCRIPTION QTY.1. KE50556-1 Probe, Water Level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 5 - CLEANING

11. KE000714-4 Pressure Gauge, for units built prior to February 2005 . . . . . . . . . . . . . . . . . . .1KE50429-5 Pressure Gauge, for units built

Page 6 - OPERATING INSTRUCTIONS

CONTROL CONSOLE COMPONENTS - HAND TILT444543

Page 7 - APPROXIMATE BOILING

CONTROL CONSOLE COMPONENTS - HAND TILTITEM NO. PART NO. DESCRIPTION QTY.1. FA11134 Screw, 10-24 x 3/8" SS . . . . . . . . . . . . . . . . . . .

Page 8 - CLEANING INSTRUCTIONS

CONTROL CONSOLE COMPONENTS - POWER TILT414240444543

Page 9

CONTROL CONSOLE COMPONENTS - POWER TILTITEM NO. PART NO. DESCRIPTION QTY.1. KE503252 Gear Box Lid . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 10 - SERVICE PARTS

TRUNNION ASSEMBLYITEM PART DESCRIPTION QTY.NO. NO.1. KE00354 TRUNNION BEARING ASSEMBLY . . . . . .1(INCLUDES PART # 3 & 6)2. KE00351 TRUNNION BEA

Page 11 - HINGE ASSEMBLY

SPARE PARTS LISTITEM ON. DESCRIPTION QTY. QTY.DOMESTIC OVERSEASRefer to Kettle Bottom & Side for parts drawingKE00458 Solid State Control Box 1 1K

Page 12 - KETTLE BOTTOM & SIDE

Shut off power at main fuse disconnect prior to servicing.Ensure kettle is at room temperature and pressure gauge is showing zero or less prior to

Page 13

Cleveland Range equipment requires little preventative maintenance. We do however provide the followingchart as a guideline for inspection and mainten

Page 14

CALIBRATING PROCEDURE1. Insure the unit has a vacuum before you begincalibrating procedures. If unit requires venting referto Kettle Venting Instructi

Page 15

3. Pull Pressure Relief Valve (A) open to insure vesselis not pressurized.4. Remove Pressure Relief Valve (A).5.Replace Pressure Relief Valve (A) with

Page 16

LUBRICATION PROCEDURELubricate the following parts every three months toinsure smooth operation and reduce wear.TRUNNIONHOUSING,WORM SCREWAND TILT GEA

Page 17

KETTLE JACKET CLEANOUT AND PASSIVATION PROCEDURESThe following procedure should be preformed at least once every three years to prevent possible corro

Page 18 - TANGENT DRAW-OFF VALVE

Fault Isolation ProcedureStep Test1. Is there proper incoming voltage atterminal block?2. Is the red LED illuminated?3. Is the green LED illuminated?4

Page 19 - SPARE PARTS LIST

Fault Isolation ProcedureStep Test1. In a cold state, does the pressure gaugeread in the green zone?2. Do the contactors shut off too early?(before re

Page 20 - IMPORTANT!

5. Remove kettle thermistor and allow tocool. Remove edge connector fromcontrol box. Test resistance across edgeconnector's pins #2 and #7. Is it

Page 21 - PROCEDURE

WIRING DIAGRAM200-240vOUTSIDEOF NORTHAMERICALIMIT

Page 22 - PROCEDURES

WIRING DIAGRAM380-600vOUTSIDEOF NORTHAMERICALIMIT

Page 23 - 3/8" Allen wrench

GENERAL Installation of the kettle must be accomplished byqualified electrical installation personnel workingto all applicable local and national code

Page 24

RECOMMENDED FLOORDRAIN DETAILASSEMBLYPosition the kettle in it's permanent location, andlevel the kettle by turning the adjustable flangedfeet. O

Page 25 - DIAGNOSTIC GUIDE

INSTALLATION CHECKSAlthough the kettle has been thoroughly testedbefore leaving the factory, the installer isresponsible for ensuring the proper opera

Page 26

OPERATING INSTRUCTIONSGeneral Parts DrawingITEM # DESCRIPTION FUNCTION1. On-Off Switch/Solid State Turns kettle ON/OFF and allows the operator to adju

Page 27

OPERATING THE KETTLEDO NOT LEAN ON OR PLACE OBJECTS ONKETTLE LIP. SERIOUS INJURY COULD RESULTIF KETTLE TIPPED OVER, SPILLING HOTCONTENTS.1. Before tur

Page 28 - OF NORTH

CARE AND CLEANINGCooking equipment must be cleaned regularly tomaintain its fast, efficient cooking performance andto ensure its continued safe, relia

Page 29 - 380-600v

STAINLESS STEEL EQUIPMENT CARE AND CLEANING(Suppied courtesy of Nafem. For more information visit their web site at www.nafem.org)Contrary to popular

Commentaires sur ces manuels

Pas de commentaire