1333 East 179th St., Cleveland, Ohio, U.S.A. 44110Phone: (216) 481-4900 Fax: (216) 481-3782Visit our web site at www.clevelandrange.comSE95036 Rev.
FAUCET ASSEMBLYITEM PART DESCRIPTION QTY.NO. NO.1. KE50825-5 3/4" Spout . . . . . . . . . . . . . . . . . . . . . .1(KEL-25/30/40/60/80/100 &
HINGE ASSEMBLY153213126471181099ITEM NO. PART NO. DESCRIPTION QTY.Hinge Assembly1. - 11 KE50597-1 25 - 40 Gallon, 20 Gallon Full Jacketed . . . . . .
ITEM NO. PART NO. DESCRIPTION QTY.1. KE50556-1 Probe, Water Level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
11. KE000714-4 Pressure Gauge, for units built prior to February 2005 . . . . . . . . . . . . . . . . . . .1KE50429-5 Pressure Gauge, for units built
CONTROL CONSOLE COMPONENTS - HAND TILT444543
CONTROL CONSOLE COMPONENTS - HAND TILTITEM NO. PART NO. DESCRIPTION QTY.1. FA11134 Screw, 10-24 x 3/8" SS . . . . . . . . . . . . . . . . . . .
CONTROL CONSOLE COMPONENTS - POWER TILT414240444543
CONTROL CONSOLE COMPONENTS - POWER TILTITEM NO. PART NO. DESCRIPTION QTY.1. KE503252 Gear Box Lid . . . . . . . . . . . . . . . . . . . . . . . . . .
TRUNNION ASSEMBLYITEM PART DESCRIPTION QTY.NO. NO.1. KE00354 TRUNNION BEARING ASSEMBLY . . . . . .1(INCLUDES PART # 3 & 6)2. KE00351 TRUNNION BEA
SPARE PARTS LISTITEM ON. DESCRIPTION QTY. QTY.DOMESTIC OVERSEASRefer to Kettle Bottom & Side for parts drawingKE00458 Solid State Control Box 1 1K
Shut off power at main fuse disconnect prior to servicing.Ensure kettle is at room temperature and pressure gauge is showing zero or less prior to
Cleveland Range equipment requires little preventative maintenance. We do however provide the followingchart as a guideline for inspection and mainten
CALIBRATING PROCEDURE1. Insure the unit has a vacuum before you begincalibrating procedures. If unit requires venting referto Kettle Venting Instructi
3. Pull Pressure Relief Valve (A) open to insure vesselis not pressurized.4. Remove Pressure Relief Valve (A).5.Replace Pressure Relief Valve (A) with
LUBRICATION PROCEDURELubricate the following parts every three months toinsure smooth operation and reduce wear.TRUNNIONHOUSING,WORM SCREWAND TILT GEA
KETTLE JACKET CLEANOUT AND PASSIVATION PROCEDURESThe following procedure should be preformed at least once every three years to prevent possible corro
Fault Isolation ProcedureStep Test1. Is there proper incoming voltage atterminal block?2. Is the red LED illuminated?3. Is the green LED illuminated?4
Fault Isolation ProcedureStep Test1. In a cold state, does the pressure gaugeread in the green zone?2. Do the contactors shut off too early?(before re
5. Remove kettle thermistor and allow tocool. Remove edge connector fromcontrol box. Test resistance across edgeconnector's pins #2 and #7. Is it
WIRING DIAGRAM200-240vOUTSIDEOF NORTHAMERICALIMIT
WIRING DIAGRAM380-600vOUTSIDEOF NORTHAMERICALIMIT
GENERAL Installation of the kettle must be accomplished byqualified electrical installation personnel workingto all applicable local and national code
RECOMMENDED FLOORDRAIN DETAILASSEMBLYPosition the kettle in it's permanent location, andlevel the kettle by turning the adjustable flangedfeet. O
INSTALLATION CHECKSAlthough the kettle has been thoroughly testedbefore leaving the factory, the installer isresponsible for ensuring the proper opera
OPERATING INSTRUCTIONSGeneral Parts DrawingITEM # DESCRIPTION FUNCTION1. On-Off Switch/Solid State Turns kettle ON/OFF and allows the operator to adju
OPERATING THE KETTLEDO NOT LEAN ON OR PLACE OBJECTS ONKETTLE LIP. SERIOUS INJURY COULD RESULTIF KETTLE TIPPED OVER, SPILLING HOTCONTENTS.1. Before tur
CARE AND CLEANINGCooking equipment must be cleaned regularly tomaintain its fast, efficient cooking performance andto ensure its continued safe, relia
STAINLESS STEEL EQUIPMENT CARE AND CLEANING(Suppied courtesy of Nafem. For more information visit their web site at www.nafem.org)Contrary to popular