SYMPTOM CAUSE REMEDY (See Text)
A timer does not count down when the
compartment is hot
The thermostatic switch is not closing.
Inoperative timer board.
There is no 5-5 VAC signal to the timer
board.
Poor wiring connections from the thermal
switch to the timer board.
Replace the thermostatic switch
Replace the timer board-Check the power
supply board, cable assemblies, and
connections. Repair or replace as necessary.
Check the cable assemblies, wire harness, and
connections. Repair or replace as necessary.
Pressing a control panel switch pad for one
compartment causes the controls of the other
compartment to respond.
Damaged or inoperative control panel
(membrane switch or ribbon connector).
Replace the control panel.
The timer display digits appear incomplete or
the indicator LED’s do not light.
Damaged or inoperative timer board The timer
board is water-soaked.
Replace the timer board. Dry the timer board.
The alarm sounds continuously (sound could be
a low-pitched whistling).
The power supply board is water soaked.
The alarm is snorted.
Damaged or short-circuited cable assembly.
Damaged or inoperative timer board.
Dry the power supply board.
Replace the power supply board.
Check the cable assemblies and connections.
Repair or replace as necessary
Replace the timer board.
The flow of steam into a compartment will not
shut off
The emergency by-pass switch is in the "on"
position. Dirt or foreign material is jammed in
the solenoid valve.
Damaged or short-circuited timer board.
Turn off the switch Repair or replace the
solenoid valve. Replace the timer board-
The time entry will not hold in the display -
one
or both display digits change continuously
Damaged or inoperative control panel
(membrane switch or ribbon connector).
Replace the control panel.
When the "Start/Cancel" pad or "Manual
Operation" pad is pressed, the compartment
steam solenoid valve opens, then closes
immediately.
Insufficient supply voltage (120 VAC nominal)
to the timer control box.
Check the building's supply voltage to the
equipment and check the wiring to the timer
control box. Repair as necessary.
Cleveland Range, Inc.
UNITED STATES CANADA
1333 East 179th St. Cleveland, Ohio 44110 Garland Commercial Ranges
Phone: (216) 481-4900 Telex: 98-0546 FAX: (216) 481-3782 1177 Kamato Road
Misassaugha, Ontario, Canada L4W1X4 Phone:
(416) 624-0260 • FAX: (416) 624-0623
Vue de la page 16
1 2 ... 12 13 14 15 16 17 18 19 20 21 22 ... 38 39

Commentaires sur ces manuels

Pas de commentaire