Lubricants that should NEVER be used in the oil well of the reducer:
1. Motor Oil
2. Automotive Gear Oil
3. Grease
4. EP Oils
21
LUBRICATION INFO
Proper installation or your worm gear speed reducer is essential for efficient,
economical operation and a long operating life. The unit is built for proper
operation in the mounting position ordered. Tilted or different mounting
positions may require factory installed lubrication provisions.
Proper lubrication is crucial to obtaining the highest possible performance and
efficiency. All "A" series mixer drives are shipped from the factory WITHOUT oil.
Due to the nature of the worm gear's sliding and rolling actions, the lubricants
listed on the next page must be used.
INSTALLATION
OIL CHANGES
Check the oil level while the unit is not in operation. Add oil when the oil level
has gone below the fill line **Make sure to never mix oils. Drain and flush the
gear housing after the first 150 hours of operation.
The regular maintenance schedule should be as follows:
Drain the oil and flush after every 6 months of normal service (8 hours of
operation per day - 7 days per week, normal operating temperature).
Drain the oil and flush after every 3 months of heavy service (24 hours - 7
days per week) or (8 hours per day - 7 days per week in extreme
temperatures or extreme environments).
All input and output bearings used in Cleveland's "A" series mixers are factory
packed with NLGI grade 2 grease. This grease is mineral based with lithium
base thickener. Repack the bearings using the same grade of grease during all
normal oil change intervals.
GREASE LUBRICATED BEARINGS