LUBRICATION INFO - ALD SERIES
All units are shipped from the factory
WITHOUT oil. Units should be filled to
the level plug.
Check oil level periodically when the
unit is not operating. Add oil if
necessary. Drain and flush housing
after first 150 hours of operation.
Drain the oil and flush after every 6
months of normal service or after
every 3 months of heavy or severe
service (around the clock operation
or harsh operating environment). If
ambient temps are below 15° F, a
winter lubricant must be added since
AGMA 7 & 8 oils will solidify.
Suppliers of industrial lubricants
should be contacted to supply suitable
lubricants to meet AGMA
specifications (please see page 22
for oil recommendations)
Oil drain plug
Sight guage
Fill Line
(some units may have
several grease fittings
on both the reducer, motor
and stuffing box. Make
sure to grease all zerk
fittings on gear case.)
Grease fitting for low/high
speed bearings
Grease Lubricated Bearings - The low speed shaft bearings are provided with grease fittings. These
bearings are packed at assembly with a lithium base grease NLGI grade 2 with EP additives.
(Cleveland recommends Mobil or Shell - Durina SD2 / NLGI grade 2 bearing grease)
BEARING GREASE